If measured temperature is lower than the minimum threshold value, the ECM sets DTC P0118.
(In this case, the input signal voltage is the maximum threshold vaue.)
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Signal check, high | 1. Poor connection 2. Open or short to power in signal circuit 3. ECTS |
Enable Conditions |
•
- | |
Threshold Value |
•
ECT sensor voltage > 4.9 V(-40 ℃/-40 °F) | |
Diagnostic Time |
•
Continuous | |
MIL ON Condition |
•
2 driving cycles |