DTC Description

The downstream heated oxygen sensor (HO2S) is forced rich and lean and monitored by the ECM. This DTC sets when the ECM does not detect the output of the HO2S in a calibrated amount of time.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

Case 1

DTC

Strategy

No signal activity

1.

Poor connection

2.

Short to Power in signal circuit

3.

HO2S(S1/S2)

4.

ECM

5.

Exhaust leaks

Enable

Conditions

Battery voltage > 10.7 V

Lambda = 1.1 for 9 sec.

Threshold

Value

Downstream O2S voltage > 0.65 V

Case 2

DTC

Strategy

Oscillation check : Test condition is checked at every 500 sec after oscillation check is performed

Enable

Conditions

Downstream O2S voltage > 0.65 V for 100 sec.

Fuel system status = Closed loop

1120 rpm < Engine speed < 3000 rpm

20 % < Engine load < 83 %

Mass airflow > 20 kg/h

EGT around downstream O2S > 700 ℃(1292 °F) or O2S heater voltage > 9.2 V or 0.5 < Downstream O2S voltage < 0.4

Threshold

Value

If All secondary conditions met then Fuel system open loop control Lambda = 1.1 for 9 sec.

Diagnostic Time

10 sec.

MIL ON Condition

2 Driving Cycles