DTC Description

If there is a delay or a target error between the target angle and the real angle over 5 times, the ECM sets DTC P0011.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Sensor Current check

1.

Poor connection

2.

Damaged or corroded terminals

3.

HO2S(S1)

Enable Conditions

Exhaust Gas temperature < 800 ℃(1472 °F)

0.95 < Target Lambda < 1.05

20 % < Heating ratio < 80 %

Threshold Value

Sensor Current Change calculated form Sensor Output Voltage > 190 ㎂

Diagnostic Time

Continuous

MIL ON Condition

2 driving cycles