Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Have any problems been found?

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.

▶ Go to "Power Circuit Inspection" procedure.

Control Circuit Inspection
1.

Check the fuel pump fuse (15A)

2.

IG "OFF" and disconnect Fuel Pump connector.

3.

Check the power of fuel pump side by using a multimeter. Measure the power within 3 sec after IG "ON".(ENG "OFF")

Specification :

Fuel pump operates for about 7-8 seconds in normal condition after IG "ON".

(Approx. 0V →12V →0V)

4.

Is the measured voltage within specification?

▶ Repair as necessary and go to "Verification of vehicle Repair" procedure.

▶ Go to "Component Inspection" procedure.