This is special function that engine can be started for moving to an area where the key learning is processed with twice IG ON.
This function is only performed in condtion that Engine EMS, Smart key ECM , Transponder, ESCL are all virgin status.
Engine can be started by the sequence.
■ Ignition ON with no cranking , Ignition OFF, Ignition ON with cranking within a time interval
■ The following timing conditions have to be fulfilled for successful start :
- PCM/ECM, Smart key ECM , Transponder are all virgin status
First Ignition ON more than 0.5 seconds and less than 1.5 seconds
Ignition OFF time is limited by the minimum of 0.2 seconds and the maximum of 1.5 seconds.
Ignition ON
The number of engine starts by "twice ignition on" is limited. The maximum value is 32 times regardless of cranking.