Connect "A/T solonoid valve"connector and GDS to Data Link Connector(DLC).
Engine ON and operate Input speed sensor.
Measure waveform between signal of Input speed sensor harness and chassis ground.
Specification : See specification waveform
Is the measured waveform within specifications?
![]() | ▶ Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair as necessary and go to "Verification Vehicle Repair" procedure. |
![]() | ▶ Go to"TCM Inspection" procedure. |
Ignition off & Engine Off.
Disconnect "ATM solenoid valve connector.
Connect GDS to Data Link Connector(DLC) and select Simulation mode.
Input specification frequency to signal of Input speed sensor by simulation mode.
Fig 1) INPUT 150Hz → 248rpm
Fig 2) INPUT 250Hz → 413rpm
※ The values are subject to change according to vehicle model or conditions.
Is measured Input speed sensor value changed by input frequency?
![]() | ▶ Substitute with a known-good Input speed sensor and then go to "Verification of Vehicle Repair" procedure. |
![]() | ▶ Substitute with a known-good TCM and check for proper operation.If the problem is corrected, replace TCM and then go to "Verification of Vehicle Repair" procedure. |