DTC Description

The SRSCM sets DTC B147600 if there is a short to power in DCAB harness.

*In this case, SRSCM checks if there's any fault in circuit by sending current for a while.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

Check Voltage

1.

Short to power in DCAB harness.

2.

Poor connection of connected part.

3.

Poor connection between shorting bar and release pin.

4.

Faulty DCAB.

5.

Check SRSCM.

Enable Conditions

Ignition "ON"

Threshold Value

Short to power in DCAB

Squib line voltage is < 3.1 kΩ (When Batt 7.4~18.7V

Diagnostic Time

Qualification

More than 3s (300ms x 10)

De-Qualification

More than 6s (300ms x 20)