DTC Description

The HECU monitors the battery voltage by reading the value of voltage.

When the voltage is lower than the expected normal value, this code is set.

The ABS/TCS/ESC functions are prohibited and the EBD function is allowed on LOW VOLTAGE CONDITION, the ABS/EBD/TCS/ESC function are prohibited on UNDER VOLTAGE CONDITION.

If the voltage recovers, to within normal operating ranges, then the controller returns to normal operations as well.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Battery Voltage Monitoring

1.

Poor connection in power supply circuit (ABS)

2.

Faulty HECU

Monitoring Period

Continuous

Case1

(Low voltage)

Enable

Conditions

When Vign is lower than 9.4±0.5V for more than 500ms in speed of over 6Kph(3.7mph).

- If IGN voltage is recovered to 9.8±0.5V, the system recovers to normal state

Fail-Safe

The ABS/ESP(ESC) functions are inhibited

The ABS/ESP(ESC) warning lamps are activated

Case2

(Under voltage)

Enable

Conditions

When Vign is lower than 7.6±0.5V for more than 500ms in speed of over 6Kph(3.7mph).

- If IGN voltage is recovered to 7.8±0.5V, the system recovers to normal state

Fail-Safe

The ABS/EBD/ESP(ESC) functions are inhibited

The ABS/EBD/ESP(ESC) warning lamps are activated