DTC Description

The HECU monitors the operation of the valves by checking the drive circuit of the solenid valves, and then sets this code when the unexpcted drive voltage is detected.

For example, the HECU sets the DTC if the electrical feedback signal does not match the actuation signal for the corresconding valve.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

Voltage Monitoring

1.

Faulty HECU

Case 1

Monitoring Period

Once when Vveh is over 30kph(18.6mph) after ignition on

Enable

Conditions

When the fault from valve is detected by monitoring valve feedback signal at the test. (The test acutuate valve in series and monitors short fault of valve lines.)

- Stop ABS/EBD/ESP(ESC) control immediately when a fault occurs

Case 2

Monitoring Period

In case of BLS ON, once when Vveh is over 15kph after ignition on

In case of BLS OFF, once when Vveh is over 6kph after ignition on

Enable

Conditions

Monioring if the electrical feedback signal mismatch the unactuation signal to the corresponding valve for more than 40ms or actuation signal over 60ms. Monitoring system reports a failure if the situation is the same after 60ms from the timing

- Stop ABS/EBD/ESP(ESC) control immediately when a fault occurs

Fail Safe

The ABS/EBD/ESP(ESC) functions are inhibited

The ABS/EBD/ESP(ESC) warning lamps are activated