Removal And Installaion
Cooling fan assembly
1.

Disconnect the battery "-" terminal.

2.

Remove the air cleaner assembly.

(Refer to Intake And Exhaust System-"Air Cleaner")

3.

Disconnect the over flow hose (A).

4.

Disconnect the cooling fan coonector (A).

5.

Remove the filler neck bolts (A).

Tightening torque :

6.9 ~ 10.8 N.m (0.7 ~ 1.1 kgf.m, 5.1 ~ 8.0 lb-ft)

6.

Remove the cooling fan assembly (A).

Tightening torque :

4.9 ~ 7.8 N.m (0.5 ~ 0.8 kgf.m, 3.6 ~ 5.8 lb-ft)

7.

Install in the reverse order of removal.

Resister
1.

Disconnect the battery "-" terminal.

2.

Disconnect the wire harness connector (A) and the fan motor connector (B).

3.

Remove the resister (A) from the cooling fan shroud.

Tightening toraue :

1.8 ~ 2.5 N.m (0.18 ~ 0.25 kgf.m, 1.3 ~ 1.8 lb-ft)

4.

Install in the reverse order of removal.

Disassembly
1.

Remove the cooling fan (A) from the cooling fan assembly.

2.

Disconnect the fan motor connector (A) from the resistor.

3.

Loosen the screws and then remove the fan motor (A) from the cooling fan shroud.

Tightening torque:

3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ 4.3 lb-ft)

4.

Assemble in the reverse order of disassembly.

Inspection
Fan Motor
1.

Disconnect the fan motor connector from the resistor.

2.

Connect the battery voltage to the "+" terminal and ground to "-" terminal.

3.

Check the cooling fan motor operates well.

Яндекс.Метрика