WGT(Waste Gate Turbocharger) is the device which increases the efficiency of turbocharger at low rpm and lasts optimum turbo efficiency at high rpm as varying the cross sectional area through which exhaust gas passes turbocharger impeller. It relieves turbo lag at low speed and increse engine power genetation.
Engine speed, APS signal, MAFS and Boost pressure sensor information is inputted to ECM.
ECM actuates vacuum diafragm which controls exhaust gas line as contrFolling WGT Control solenoid valve duty to maintain optimum state of air compression.
P0047 is set when "0"A is detected in WGT Control solenoid valve control circuit for more than 1 sec.. This code is due to open or short to ground in WGT Control solenoid valve circuit, or open in WGT Control solenoid valve component.
Item | Detecting Condition | Possible Cause | ||
DTC Strategy |
•
Signal monitoring |
•
WGT Control solenoid valve circuit
•
WGT Control solenoid valve component | ||
Enable Conditions |
•
IG KEY ON | |||
Threshold Value |
•
Short to GND, wiring open | |||
Diagnostic Time |
•
4000ms | |||
Fail Safe | Fuel cut | NO | ||
EGR Off | YES | |||
Fuel Limit | YES | |||
MIL | NO |
WGT Control solenoid valve component resistance | WGT Control solenoid valve operating Hz | WGT Control solenoid valve operating duty |
14.7 ~ 16.1Ω (20℃) | 300Hz | 79% at idle, decreases as accelerating |
Fig.1) WGT Control solenoid valve output waveform at 79% duty. Duty decreases as boost pressure increases.
Fig.2) WGT Control solenoid valve duty decreased at acceleration.