The Ambient Temperature is a NTCT type thermistor and is use for temperature regulation including blower motor level and mix mode control .
The Air conditioner Control Module sets DTC B1238 if Ambient sensor has been detected over 4.9V for 0.3 seconds.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Voltage check |
•
Poor Connection in harness
•
Open in signal circuit
•
Shrot to battery in signal circuit
•
Faulty Ambient Temperature sensor
•
Faulty air condtioner control Module |
Enable Conditions |
•
IG KEY ON | |
Threshold value |
•
Ambient Temperature sensor has been detected over 4.9V for 0.3 seconds | |
Failsafe |
•
Displayed '--' and A/C control Module regards and controls it as 20℃(68℉) |
Temperature(℃/℉) | Resistance(㏀) | Temperature(℃/℉) | Resistance(㏀) |
-20/-4 | 271.4 | 50/122 | 11 |
0/32 | 95.1 | 80/140 | 3.8 |
25/77 | 30 | - | - |