Component Location
General Description

The Duct Sensor has a function to measure the temperature of HAVC. The Air conditioner Control Module gets the feedback from it and uses to make a temperature control promptly and accurately.

DTC Description

The Air conditioner Control Module sets DTC B1288 if Duct sensor(Floor) signal voltage has been detected below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

Short in signal circuit.

Faulty Duct Sensor.

Faulty A/C control Module.

Enable Conditions

IG KEY ON

Threshold value

Duct sensor has been dtected 0.1V for 0.3 seconds.

Failsafe

-

Specification
※ Resistance value of sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-40/-40

990

25/77

30

-20/-4

290

85/185

3.2

0/32

97

-

-

Diagnostic Circuit Diagram
Яндекс.Метрика