Remove "IGNITION COIL", and measure the resistance between "IGNITION COIL_Power" terminal and "IGNITION COIL_Control" terminal.
■ Specification : 0.637 Ω ~ 0.863 Ω (20℃, 68℉)
Is the measured primary coil resistance value normal ?
![]() | ▶ Go to "Primary ignition signal waveform inspection" procedure as below. |
![]() | ▶ Replace the ignition coil. |
Select oscilloscope function on the GDS and connect channel "A" of the VMI to "Ignition Coil Control" terminal of "ECM/PCM" harness connecter.
Measure the signal waveform of the primary ignition at IG key "START".
■ Reference signal waveform
Is the measured primary ignition's signal waveform normal ?
![]() | ▶ Click on "Ignition coil circuit" item for more details. |
![]() | ▶ Replace the ignition coil. |