IGNITION COIL
Primary resistance inspection
1.

Remove "IGNITION COIL", and measure the resistance between "IGNITION COIL_Power" terminal and "IGNITION COIL_Control" terminal.

■ Specification : 0.637 Ω ~ 0.863 Ω (20℃, 68℉)

2.

Is the measured primary coil resistance value normal ?

▶ Go to "Primary ignition signal waveform inspection" procedure as below.

▶ Replace the ignition coil.

Primary ignition signal waveform inspection
3.

Select oscilloscope function on the GDS and connect channel "A" of the VMI to "Ignition Coil Control" terminal of "ECM/PCM" harness connecter.

4.

Measure the signal waveform of the primary ignition at IG key "START".

■ Reference signal waveform

5.

Is the measured primary ignition's signal waveform normal ?

▶ Click on "Ignition coil circuit" item for more details.

▶ Replace the ignition coil.