The burglar alarm system is armed automatically after the doors, hood, and tailgate are closed and locked.
The system is set off when any of the following occurs :
A door is forced open.
The tailgate is opened.
The hood is opened.
When the system is set off, the alarm sounds and the hazard lamp flash for about 30 seconds or until the system is disarmed by passing the unlock button ON the transmitter or door key.
For the system to arm, the ignition switch must be off and the key removed. Then, the body control module must receive signals that the doors, hood, and tailgate are closed and locked. When everything is closed and locked, none of the control unit inputs are grounded.
The door switches, hood switch and tailgate switch are all close and lock the doors with the remote transmitter and then the system arms after 30s.
If anything is opened after the system is armed, the body control module gets a ground signal from that switch, and the system is set off.
If one of the switches is misadjusted or there is a short in the system, the system will not arm. As long as the body control module continues to get a ground signal, it thinks the vehicle is not closed and locked and will not arm.
The burglar alarm system is integrated with the keyless entry system. The keyless entry system allows you to lock and unlock the vehicle with the remote transmitter. When you push the LOCK button, all doors lock. When you push the UNLOCK button again, all doors unlock.
The room lamp, if its switch is in the center position, will come on when you press the UNLOCK button. If you do not open a door, the light will go off in about 30 seconds, the doors will automatically relock, and the burglar alarm system will rearm. If you relock the doors with the remote transmitter within 30 seconds, the light will go off immediately.
You cannot lock or unlock the doors with the remote transmitter if the key is in the ignition switch.
The system will signal you when the doors lock and unlock by flashing the hazard lamp once when they lock and closed, and twice when they unlock.
DOOR LOCK / UNLOCK and tailgate operations are performed with remocon
Keyless entry function is performed in a state that key in SW is eliminated from key cylinder
LOCK / UNLOCK and tailgate signals are received from the transmitter and DOOR LOCK / UNLOCK and tailgate signals are output.
In case of tailgate, this operation is performed when pushing the button for 1s or more.
Transmission Distance : 30m or more from outside of the car
Registration procedure of the transmitter
In registration mode, it shall be possible to register up to Max 4EA.
At re-registration, data are registered newly after deleting the previous TX DATA
No. | Saved code | Code to change | Changed code |
1 | A | C | C (A is deleted) |
2 | A, B, C, D | E | E (A, B, C, D is deleted) |
3 | A, B | C, D, E | C, D |
4 | A, B | C, C, D | C |
For the registration procedures by using GDS, refer to "TRANSMITTER CODE REGISTRATION".
Transmitter signal & Receiver Spec
Transmission signal
Transmit relevant transmission DATA (Transmission frame) twice by pushing TX SW.
Only LOCK signal is output when pushing TX LOCK SW and UNLOCK SW at the same time.
State | Description |
Initial Condition | ALARM state |
Event | IGN KEY ON during 30sec |
ALT 'L' is ON | |
Any door open and TX(Transmitter) unlock | |
Any door open (4Door + Tailgate) and TX(Transmitter) lock | |
TX(Transmitter) Tailgate or SMK Passive input | |
TX(Transmitter) lock confirm fail | |
AUTH (Authentication : Only SMK) | |
Action | The state goes to DISARM state |
H2 (Any door open and TX(Transmitter) unlock, Only TX(Transmitter) tailgate | |
Stop alarm pattern |
State | Description |
Initial Condition | DISARM state |
Event | Any door open and TX(Transmitter) unlock |
Any door open and AUTH (Authentication : Only SMK) | |
Action | Maintain DISARM state |
H2 [Hazard relay on (Twice)] |
State | Description |
Initial Condition | ARM WAIT State |
Event | Key in switch ON |
Any open | |
Any door is unlocked | |
AUTH (Authentication : Only SMK) | |
TX(Transmitter) Tailgate or SMK Passive input | |
Action | The state goes to DISARM state |
State | Description |
Initial Condition | AUTO LOCK TIMER 1 State |
Event | Any open |
Key in | |
TX(Transmitter) lock confirm fail | |
Auto lock confirm fail | |
AUTH (Authentication : Only SMK) | |
Action | The state goes to DISARM state |
State | Description |
Initial Condition | AUTO LOCK TIMER 2 State |
Event | Any door open |
Key in | |
TX(Transmitter) lock confirm fail | |
Auto lock confirm fail | |
AUTH (Authentication : Only SMK) | |
Action | The state goes to DISARM state |
State | Description |
Initial Condition | ARM State |
Event | IGN Key ON |
AUTH (Authentication : Only SMK) | |
Action | The state goes to DISARM state |
State | Description |
Initial Condition | REARM State |
Event | IGN Key ON for 30sec |
All ON | |
TX(Transmitter) lock confirm fail | |
TX(Transmitter) Tailgate | |
AUTH (Authentication : Only SMK) | |
Action | The state goes to DISARM state |
H2 [Only TX(Transmitter) Tailgate] |
State | Description |
Initial Condition | PREARM State |
Event | Any door open and TX(Transmitter) unlock |
Key in switch ON | |
All entranced closed and Any door is unlocked | |
AUTH (Authentication : Only SMK) | |
Action | The state goes to DISARM state |
H2 [Any door open and TX(Transmitter) unlock] |
State | Description |
Initial Condition | Auto lock timer3 |
Event | Key in switch ON |
4Door open | |
Hood open | |
TX(Transmitter) confirm fail | |
AUTH (Authentication : Only SMK) | |
Action | The state goes to DISARM state |
State | Description |
Initial Condition | ARM state |
Event | Tx Lock |
Action | No state change |
Hazard relay 1Time on(1sec) |
State | Description |
Initial Condition | ARM WAIT state |
Event | ARM WAIT TIMER is expired |
Action | The state goes to ARM state |
LED is Blinking
State | Description |
Initial Condition | ARM state |
Event | Any open |
Action | The state goes to ALARM state |
Start ALARM Rattern. |
State | Description |
Initial Condition | REARM state |
Event | Any open |
Action | The state goes to ALARM state |
Start ALARM Rattern. |
T1 : 0.4~0.5sec, T2 : 27 ± 2sec.
State | Description |
Initial Condition | ARM WAIT state |
Event | Tx Lock |
Action | NO state change Hazard relay 1 Time on |
State | Description |
Initial Condition | DISARM State & All close |
Event | TX(Transmitter) lock confirm |
Action | The state goes to DISARM state |
H1 (Only Tx lock confirm) | |
Start ARM WAIT TIMER |
State | Description |
Initial Condition | ALARM state and All close |
Event | TX(Transmitter) lock confirm |
Action | The state goes to ARM WAIT state |
H1 (Only Tx lock confirm) | |
Stop ALARM PATTERN | |
Start ARM WAIT TIMER |
State | Description |
Initial Condition | AUTO LOCK TIMER1 State |
Event | Auto lock confirm |
Tx lock confirm | |
Action | ARM WAIT State |
H1 (Only Auto lock confirm, Tx lock confirm) | |
Start ARM WAIT TIMER |
State | Description |
Initial Condition | PREARM State |
Event | All close and All door lock |
Action | The state goes to ARM WAIT state |
Start ARM WAIT TIMER | |
H1 (Hazard relay 1 time ON) |
State | Description |
Initial Condition | REARM State |
Event | TX(Transmitter) lock confirm |
Action | The state goes to ARM WAIT state |
H1 (Only Tx lock confirm) | |
Start ARM WAIT TIMER |
State | Description |
Initial Condition | AUTO LOCK TIMER3 |
Event | TX(Transmitter) lock confirm |
Action | The state goes to ARM WAIT state |
H1 (Only Tx lock confirm) | |
Start ARM WAIT TIMER |
State | Description |
Initial Condition | ALARM state |
Event | All entrance is closed & Alarm Patten finished |
Action | The state goes to REARM state |
State | Description |
Initial Condition | ARM state |
Event | Tx Unlock |
Action | The state goes to AUTO LOCK TIMER1 state |
Start AUTO LOCK TIMER1 | |
Hazard relay Twice on |
State | Description |
Initial Condition | AUTO LOCK TIMER1 |
Event | TX(Transmitter) unlock confirm AUTO LOCK TIMER1 is expired |
Action | The state goes to ARM WAIT state |
Restart AUTO LOCK TIMER1 (Only Tx unlock) | |
H2 (Only Tx unlock) | |
Auto lock (Only AUTO LOCK TIMER1) is expired |
State | Description |
Initial Condition | ARM WAIT state |
Event | Tx Unlock |
Action | The state goes to AUTO LOCK TIMER1 state |
Start AUTO LOCK TIMER1 | |
H2 (Hazard relay Twice on) |
State | Description |
Initial Condition | DISARM state & All entrances closed (DOORS, HOOD & Tailgate) |
Event | Tx Unlock |
Action | The state goes to AUTO LOCK TIMER1 state |
Start AUTO LOCK TIMER1 | |
H2 (Hazard relay Twice on) |
State | Description |
Initial Condition | ALARM state & All entrances are closed (DOORS, HOOD & Tailgate) |
Event | Tx Unlock |
Action | The state goes to AUTO LOCK TIMER1 state |
Start AUTO LOCK TIMER1 | |
H2 (Hazard relay Twice on) | |
Stop alarm pattern | |
Horn relay off |
State | Description |
Initial Condition | REARM state |
Event | Tx Unlock |
Action | The state goes to AUTO LOCK TIMER1 state |
Start AUTO LOCK TIMER1 | |
H2 (Hazard relay Twice on) |
State | Description |
Initial Condition | AUTO LOCK TIMER3 state |
Event | Tx Unlock |
Action | The state goes to AUTO LOCK TIMER1 state |
Start AUTO LOCK TIMER1 | |
H2 (Hazard relay Twice on) |
State | Description |
Initial Condition | AUTO LOCK TIMER2 state |
Event | TX(Transmitter) unlock AUTO LOCK TIMER2 is expired |
Action | No state change |
Restart AUTO LOCK TIMER2 (Only Tx unlock) | |
H2 (Only Tx unlock) | |
Auto lock (Only AUTO LOCK TIMER2 is expired |
State | Description |
Initial Condition | DISARM state & All Doors are closed and hood is opened |
Event | Tx Unlock |
Action | The state goes to AUTO LOCK TIMER2 state |
Start AUTO LOCK TIMER2 | |
H2 (Hazard relay Twice on) |
State | Description |
Initial Condition | ALARM state & All Door are closed and hood is opened |
Event | Tx Unlock |
Action | The state goes to AUTO LOCK TIMER2 state |
Start AUTO LOCK TIMER2 | |
H2 (Hazard relay Twice on) | |
Stop ALARM PATTERN |
State | Description |
Initial Condition | PREARM state All Doors are closed & (HOOD is opened) |
Event | Tx Unlock |
Action | The state goes to AUTO LOCK TIMER2 state |
Start AUTO LOCK TIMER2 | |
H2 (Hazard relay Twice on) |
State | Description |
Initial Condition | ARM state |
Event | Tx Tailgate or SMK PASSIVE Tailgate input |
Action | The state goes to AUTO LOCK TIMER3 state |
Start AUTO LOCK TIMER3 | |
H2 (Hazard relay Twice on) |
State | Description |
Initial Condition | AUTO LOCK TIMER3 state |
Event | Tx Tailgate |
Action | Restart AUTO LOCK TIMER3 state |
The state goes to AUTO LOCK TIMER3 state | |
H2 (Hazard relay Twice on) |
State | Description |
Initial Condition | ARM WAIT state |
Event | Tx Tailgate |
Action | The state goes to AUTO LOCK TIMER3 state |
Start AUTO LOCK TIMER3 | |
H2 (Hazard relay Twice on) |
State | Description |
Initial Condition | AUTO LOCK TIMER2 state |
Event | TX(Transmitter) lock confirm |
Auto lock confirm | |
Action | The state goes to PREARM state |
State | Description |
Initial Condition | DISARM State and All door close and Hood open and TX lock |
Event | TX(Transmitter) lock confirm |
Action | The state goes to PREARM state |
State | Description |
Initial Condition | ALARM State and All door close and Hood open and Tx lock |
Event | TX(Transmitter) lock confirm |
Action | The state goes to PREARM state |
Stop ALARM PATTERN |
State | Description |
Initial Condition | AUTO LOCK TIMER3 |
Event | AUTO LOCK TIMER3 is expired |
Tailgate open | |
Action | The state goes to PREARM state |
State | Description |
Initial Condition | ALARM MODE |
Event | Taking the battery out then take on. |
Action | The state goes to ALARM mode Horn relay 1 Times on |
State | Description |
Initial Condition | ARM MODE |
Event | Taking the battery out then reconnecting |
Action | The state goes to ARM mode |
State | Description |
Initial Condition | DISARM MODE |
Event | Taking the battery out then reconnecting |
Action | The state goes to DISARM mode |
Security LED control is operated when IGN KEY OFF state
IGN KEY OFF state, Full ON control while ARM WAIT MODE entry.Except ARM WAIT MODE is BLINKING control.
BLINKING period is 2.3sec, 0.3sec ON and OFF while 2sec
T1 : 0.3 ± 0.1sec, T2 : 2 ± 0.2sec.