Description
Burglar Alarm System

The burglar alarm system is armed automatically after the doors, hood, and tailgate are closed and locked.

The system is set off when any of the following occurs :

A door is forced open.

The tailgate is opened.

The hood is opened.

When the system is set off, the alarm sounds and the hazard lamp flash for about 30 seconds or until the system is disarmed by passing the unlock button ON the transmitter or door key.

For the system to arm, the ignition switch must be off and the key removed. Then, the body control module must receive signals that the doors, hood, and tailgate are closed and locked. When everything is closed and locked, none of the control unit inputs are grounded.

The door switches, hood switch and tailgate switch are all close and lock the doors with the remote transmitter and then the system arms after 30s.

If anything is opened after the system is armed, the body control module gets a ground signal from that switch, and the system is set off.

If one of the switches is misadjusted or there is a short in the system, the system will not arm. As long as the body control module continues to get a ground signal, it thinks the vehicle is not closed and locked and will not arm.

Keyless Entry System

The burglar alarm system is integrated with the keyless entry system. The keyless entry system allows you to lock and unlock the vehicle with the remote transmitter. When you push the LOCK button, all doors lock. When you push the UNLOCK button again, all doors unlock.

The room lamp, if its switch is in the center position, will come on when you press the UNLOCK button. If you do not open a door, the light will go off in about 30 seconds, the doors will automatically relock, and the burglar alarm system will rearm. If you relock the doors with the remote transmitter within 30 seconds, the light will go off immediately.

You cannot lock or unlock the doors with the remote transmitter if the key is in the ignition switch.

The system will signal you when the doors lock and unlock by flashing the hazard lamp once when they lock and closed, and twice when they unlock.

Function
Keyless Entry Function

DOOR LOCK / UNLOCK and tailgate operations are performed with remocon

1.

Keyless entry function is performed in a state that key in SW is eliminated from key cylinder

2.

LOCK / UNLOCK and tailgate signals are received from the transmitter and DOOR LOCK / UNLOCK and tailgate signals are output.

3.

In case of tailgate, this operation is performed when pushing the button for 1s or more.

Transmitter(TX) SPEC
1.

Transmission Distance : 30m or more from outside of the car

2.

Registration procedure of the transmitter

(1)

In registration mode, it shall be possible to register up to Max 4EA.

(2)

At re-registration, data are registered newly after deleting the previous TX DATA

No.

Saved code

Code to change

Changed code

1

A

C

C (A is deleted)

2

A, B, C, D

E

E (A, B, C, D is deleted)

3

A, B

C, D, E

C, D

4

A, B

C, C, D

C

(3)

For the registration procedures by using GDS, refer to "TRANSMITTER CODE REGISTRATION".

3.

Transmitter signal & Receiver Spec

(1)

Transmission signal

A.

Transmit relevant transmission DATA (Transmission frame) twice by pushing TX SW.

B.

Only LOCK signal is output when pushing TX LOCK SW and UNLOCK SW at the same time.

DISARM
Condition 1

State

Description

Initial Condition

ALARM state

Event

IGN KEY ON during 30sec 

ALT 'L' is ON

Any door open and TX(Transmitter) unlock

Any door open (4Door + Tailgate) and  TX(Transmitter)  lock

TX(Transmitter) Tailgate or SMK Passive input

TX(Transmitter) lock confirm fail

AUTH (Authentication : Only SMK)

Action

The state goes to DISARM state

H2 (Any door open and TX(Transmitter)

 unlock, Only TX(Transmitter) tailgate

Stop alarm pattern

Condition 2

State

Description

Initial Condition

DISARM state

Event

Any door open and TX(Transmitter) unlock

Any door open and AUTH (Authentication : Only SMK)

Action

Maintain DISARM state

H2 [Hazard relay on (Twice)]

Condition 3

State

Description

Initial Condition

ARM WAIT State

Event

Key in switch ON

Any open

Any door is unlocked

AUTH (Authentication : Only SMK)

TX(Transmitter) Tailgate or SMK Passive input

Action

The state goes to DISARM state

Condition 4

State

Description

Initial Condition

AUTO LOCK TIMER 1 State

Event

Any open

Key in

TX(Transmitter) lock confirm fail

Auto lock confirm fail

AUTH (Authentication : Only SMK)

Action

The state goes to DISARM state

Condition 5

State

Description

Initial Condition

AUTO LOCK TIMER 2 State

Event

Any door open

Key in

TX(Transmitter) lock confirm fail

Auto lock confirm fail

AUTH (Authentication : Only SMK)

Action

The state goes to DISARM state

Condition 6

State

Description

Initial Condition

ARM State

Event

IGN Key ON

AUTH (Authentication : Only SMK)

Action

The state goes to DISARM state

Condition 7

State

Description

Initial Condition

REARM State

Event

IGN Key ON for 30sec

All ON

TX(Transmitter) lock confirm fail

TX(Transmitter) Tailgate

AUTH (Authentication : Only SMK)

Action

The state goes to DISARM state

H2 [Only TX(Transmitter) Tailgate]

Condition 8

State

Description

Initial Condition

PREARM State

Event

Any door open and TX(Transmitter) unlock

Key in switch ON

All entranced closed and Any door is unlocked

AUTH (Authentication : Only SMK)

Action

The state goes to DISARM state

H2 [Any door open and TX(Transmitter) unlock]

Condition 9

State

Description

Initial Condition

Auto lock timer3

Event

Key in switch ON

4Door open

Hood open

TX(Transmitter) confirm fail

AUTH (Authentication : Only SMK)

Action

The state goes to DISARM state

ARM
Condition 1

State

Description

Initial Condition

ARM state

Event

Tx Lock

Action

No state change

Hazard relay 1Time on(1sec)

Condition 2

State

Description

Initial Condition

ARM WAIT state

Event

ARM WAIT TIMER is expired

Action

The state goes to ARM state

ALARM
-

LED is Blinking

Condition 1

State

Description

Initial Condition

ARM state

Event

Any open

Action

The state goes to ALARM state

Start ALARM Rattern.

Condition 2

State

Description

Initial Condition

REARM state

Event

Any open

Action

The state goes to ALARM state

Start ALARM Rattern.

T1 : 0.4~0.5sec, T2 : 27 ± 2sec.

ARM WAIT MODE
Condition 1

State

Description

Initial Condition

ARM WAIT state

Event

Tx Lock

Action

NO state change

Hazard relay 1 Time on

Condition 2

State

Description

Initial Condition

DISARM State & All close

Event

TX(Transmitter) lock confirm

Action

The state goes to DISARM state

H1 (Only Tx lock confirm)

Start ARM WAIT TIMER

Condition 3

State

Description

Initial Condition

ALARM state and All close

Event

TX(Transmitter) lock confirm

Action

The state goes to ARM WAIT state

H1 (Only Tx lock confirm)

Stop ALARM PATTERN

Start ARM WAIT TIMER

Condition 4

State

Description

Initial Condition

AUTO LOCK TIMER1 State

Event

Auto lock confirm

Tx lock confirm

Action

ARM WAIT State

H1 (Only Auto lock confirm, Tx lock confirm)

Start ARM WAIT TIMER

Condition 5

State

Description

Initial Condition

PREARM State

Event

All close and All door lock

Action

The state goes to ARM WAIT state

Start ARM WAIT TIMER

H1 (Hazard relay 1 time ON)

Condition 6

State

Description

Initial Condition

REARM State

Event

TX(Transmitter) lock confirm

Action

The state goes to ARM WAIT state

H1 (Only Tx lock confirm)

Start ARM WAIT TIMER

Condition 7

State

Description

Initial Condition

AUTO LOCK TIMER3

Event

TX(Transmitter) lock confirm

Action

The state goes to ARM WAIT state

H1 (Only Tx lock confirm)

Start ARM WAIT TIMER

REARM MODE
Condition 1

State

Description

Initial Condition

ALARM state

Event

All entrance is closed & Alarm Patten finished

Action

The state goes to REARM state

AUTO LOCK TIMER1 MODE
Condition 1

State

Description

Initial Condition

ARM state

Event

Tx Unlock

Action

The state goes to AUTO LOCK TIMER1 state

Start AUTO LOCK TIMER1

Hazard relay Twice on

Condition 2

State

Description

Initial Condition

AUTO LOCK TIMER1

Event

TX(Transmitter) unlock confirm

AUTO LOCK TIMER1 is expired

Action

The state goes to ARM WAIT state

Restart AUTO LOCK TIMER1 (Only Tx unlock)

H2 (Only Tx unlock)

Auto lock (Only AUTO LOCK TIMER1) is expired

Condition 3

State

Description

Initial Condition

ARM WAIT state

Event

Tx Unlock

Action

The state goes to AUTO LOCK TIMER1 state

Start AUTO LOCK TIMER1

H2 (Hazard relay Twice on)

Condition 4

State

Description

Initial Condition

DISARM state & All entrances closed (DOORS, HOOD & Tailgate)

Event

Tx Unlock

Action

The state goes to AUTO LOCK TIMER1 state

Start AUTO LOCK TIMER1

H2 (Hazard relay Twice on)

Condition 5

State

Description

Initial Condition

ALARM state & All entrances are closed (DOORS, HOOD & Tailgate)

Event

Tx Unlock

Action

The state goes to AUTO LOCK TIMER1 state

Start AUTO LOCK TIMER1

H2 (Hazard relay Twice on)

Stop alarm pattern

Horn relay off

Condition 6

State

Description

Initial Condition

REARM state

Event

Tx Unlock

Action

The state goes to AUTO LOCK TIMER1 state

Start AUTO LOCK TIMER1

H2 (Hazard relay Twice on)

Condition 7

State

Description

Initial Condition

AUTO LOCK TIMER3 state

Event

Tx Unlock

Action

The state goes to AUTO LOCK TIMER1 state

Start AUTO LOCK TIMER1

H2 (Hazard relay Twice on)

AUTO LOCK TIMER2 MODE
Condition 1

State

Description

Initial Condition

AUTO LOCK TIMER2 state

Event

TX(Transmitter) unlock

AUTO LOCK TIMER2 is expired

Action

No state change

Restart AUTO LOCK TIMER2 (Only Tx unlock)

H2 (Only Tx unlock)

Auto lock (Only AUTO LOCK TIMER2 is expired

Condition 2

State

Description

Initial Condition

DISARM state & All Doors are closed and hood is opened

Event

Tx Unlock

Action

The state goes to AUTO LOCK TIMER2 state

Start AUTO LOCK TIMER2

H2 (Hazard relay Twice on)

Condition 3

State

Description

Initial Condition

ALARM state & All Door are closed and hood is opened

Event

Tx Unlock

Action

The state goes to AUTO LOCK TIMER2 state

Start AUTO LOCK TIMER2

H2 (Hazard relay Twice on)

Stop ALARM PATTERN

Condition 4

State

Description

Initial Condition

PREARM state

All Doors are closed & (HOOD is opened)

Event

Tx Unlock

Action

The state goes to AUTO LOCK TIMER2 state

Start AUTO LOCK TIMER2

H2 (Hazard relay Twice on)

AUTO LOCK TIMER3 MODE
Condition 1

State

Description

Initial Condition

ARM state

Event

Tx Tailgate or SMK PASSIVE Tailgate input

Action

The state goes to AUTO LOCK TIMER3 state

Start AUTO LOCK TIMER3

H2 (Hazard relay Twice on)

Condition 2

State

Description

Initial Condition

AUTO LOCK TIMER3 state

Event

Tx Tailgate

Action

Restart AUTO LOCK TIMER3 state

The state goes to AUTO LOCK TIMER3 state

H2 (Hazard relay Twice on)

Condition 3

State

Description

Initial Condition

ARM WAIT state

Event

Tx Tailgate

Action

The state goes to AUTO LOCK TIMER3 state

Start AUTO LOCK TIMER3

H2 (Hazard relay Twice on)

PREARM MODE
Condition 1

State

Description

Initial Condition

AUTO LOCK TIMER2 state

Event

TX(Transmitter) lock confirm

Auto lock confirm

Action

The state goes to PREARM state

Condition 2

State

Description

Initial Condition

DISARM State and All door close and Hood open and TX lock

Event

TX(Transmitter) lock confirm

Action

The state goes to PREARM state

Condition 3

State

Description

Initial Condition

ALARM State and All door close and Hood open and Tx lock

Event

TX(Transmitter) lock confirm

Action

The state goes to PREARM state

Stop ALARM PATTERN

Condition 4

State

Description

Initial Condition

AUTO LOCK TIMER3

Event

AUTO LOCK TIMER3 is expired

Tailgate open

Action

The state goes to PREARM state

RESET
Condition 1

State

Description

Initial Condition

ALARM MODE

Event

Taking the battery out then take on.

Action

The state goes to ALARM mode

Horn relay 1 Times on

Condition 2

State

Description

Initial Condition

ARM MODE

Event

Taking the battery out then reconnecting

Action

The state goes to ARM mode

Condition 3

State

Description

Initial Condition

DISARM MODE

Event

Taking the battery out then reconnecting

Action

The state goes to DISARM mode

Security LED control
1.

Security LED control is operated when IGN KEY OFF state

2.

IGN KEY OFF state, Full ON control while ARM WAIT MODE entry.Except ARM WAIT MODE is BLINKING control.

3.

BLINKING period is 2.3sec, 0.3sec ON and OFF while 2sec

T1 : 0.3 ± 0.1sec, T2 : 2 ± 0.2sec.