Inspection
1.

Ignition "OFF"

2.

Disconnect the intake actuator connector.

3.

Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal 7.

4.

Verify that the intake actuator operates to the fresh position when connecting in the reverse.

1. –

2. –

3. Recirculation

4. Sensor Ground

5. Feedback Signal

6. 5V (Vcc)

7. Fresh

5.

If the intake actuator is not operated well, substitute with a known-good intake actuator and check for proper operation.

6.

If the problem is corrected, replace the intake actuator.