Check for continuity and measure the resistance.
Check for continuity and measure the resistance between No.1 terminal and No.2 terminal of connector.
Standard value
Resistance : 2.37Ω ± 10%
Check for continuity and measure the resistance between No.1 terminal of Connecter A and No.2 terminal of Connecter C.
Standard value
Resistance : 1.42Ω ± 10%
Check for continuity and measure the resistance Connector B Between No.1 terminal and No.2 terminal.
Standard value
Resistance : 0.95Ω ± 10%
Operate the seat warmer after connecting the connectors, and then check the NTC(Negative Temperature Coefficient) thermostat by measuring the maximum temperature of seat surface.
Standard value
Cushion: 40 ± 2°C (104 ± 35.6°F)
Back : 46 (+ 2°C/-1°C) [114.8 (+35.6°F/-30.2°F)]