Inspection
1.

Check for continuity and measure the resistance.

[SET]

Check for continuity and measure the resistance between No.1 terminal and No.2 terminal of connector.

Standard value

Resistance : 2.37Ω ± 10%

[Cushion]

Check for continuity and measure the resistance between No.1 terminal of Connecter A and No.2 terminal of Connecter C.

Standard value

Resistance : 1.42Ω ± 10%

[Back]

Check for continuity and measure the resistance Connector B Between No.1 terminal and No.2 terminal.

Standard value

Resistance : 0.95Ω ± 10%

2.

Operate the seat warmer after connecting the connectors, and then check the NTC(Negative Temperature Coefficient) thermostat by measuring the maximum temperature of seat surface.

Standard value

Cushion: 40 ± 2°C (104 ± 35.6°F)

Back : 46 (+ 2°C/-1°C) [114.8 (+35.6°F/-30.2°F)]